Lighting Glossary
Twenty terms used in outdoor architectural lighting, each with a definition and the practical consequence for a project.
The terms that matter most on a façade project are DMX512, beam angle, colour temperature, RGB/RGBW, IP rating and batch consistency. Each one changes a real decision about the fixture schedule or the installation.
A
Anti-corrosion treatment
Material selection and surface treatment applied to fixtures and fixings so they withstand humid or salty outdoor environments.
For coastal and high-humidity projects, review housing finish, fixings and connectors before freezing the schedule.
Read the guide →B
Beam angle
The angular spread of light leaving a fixture. A narrow angle reaches further; a wide angle covers more area at close range.
Select the beam angle from washing height and setback distance, not from fixture wattage.
Read the guide →Batch consistency
The degree to which fixtures from different production batches match in colour temperature, colour and brightness.
On façades and bridge outlines, batch inconsistency is visible as bands or segments. Fix the colour version in the schedule before production.
Read the guide →BOM
The complete list of fixtures, accessories and control items required for a lighting project, including quantities and versions.
A confirmed BOM is the practical basis for a quotation. GDXC supports fixture schedules and control notes before pricing.
Read the guide →C
CCT
A measure of the warmth or coolness of white light, expressed in kelvin (K). Lower values look warmer, higher values look cooler.
Fix one CCT in the fixture schedule when a project uses several product families, so the façade and landscape do not look mismatched.
Read the guide →Control zone
A group of fixtures that receives the same control instruction and forms one part of a programmed lighting effect.
Zones are planned from the animation and the available control equipment before addresses are assigned.
Read the guide →D
DMX512
A digital control protocol used to dim and colour outdoor LED fixtures, sending channel values to each fixture address on a shared data line.
On a project, each DMX512 fixture occupies one or more channels. An addressing plan assigns those channels so the programmed scene controls the intended fixture. GDXC provides addressing guidance for compatible fixtures.
Read the guide →F
Flood light
A directional LED luminaire that lights a broad area or a specific surface from a distance, used on large façades, structures and open spaces.
Flood lights are chosen by power and beam angle for the surface size and mounting height, rather than by wattage alone.
Read the guide →H
Heat dissipation
The way a fixture moves heat away from the LEDs and driver, usually through an aluminium housing acting as a heat sink.
Poor heat dissipation accelerates light degradation in hot climates. Housing design is reviewed for high-temperature projects.
Read the guide →I
In-ground light
A luminaire installed at floor or ground level to light paths, landscape features and the base of a building.
The protection rating and drainage condition must be confirmed for the exact installation position.
Read the guide →IP rating
A two-digit code describing protection against solid objects and water. The first digit covers solids, the second covers water.
The right rating depends on the installation position. GDXC confirms the rating for the exact model rather than publishing a single blanket figure.
Read the guide →L
Linear light
A long, narrow LED luminaire used for building outlines, bridge edges and continuous architectural lines.
Batch consistency matters on a linear run because a colour difference between fixtures becomes visible as segments in the line.
Read the guide →M
MOQ
The smallest quantity a supplier will accept for an order or a specific model.
GDXC does not publish a fixed MOQ. Quantities and lead times are confirmed per model and project.
Read the guide →O
OEM / ODM
OEM supplies products under a customer brand; ODM adapts a product design or specification to a customer requirement.
GDXC supports OEM and ODM requests including packaging, labelling and project-specific adjustments, confirmed per model.
Read the guide →P
Pixel light
An individually addressable LED point that can change colour and brightness as part of a dynamic façade or media display.
Pixel spacing is selected from viewing distance and the detail level of the content, then translated into control zones.
Read the guide →R
RGB
A colour-mixing method using red, green and blue LEDs. Mixing the three channels produces a wide range of colours, including white approximations.
RGB can produce white by mixing, but the result is less natural than a dedicated white channel and varies more between batches.
Read the guide →RGBW
A colour system with red, green, blue and a dedicated white LED channel, giving cleaner white light as well as saturated colours.
For hotels and architectural façades where white and colour are both used, RGBW avoids the compromise of mixed-white RGB.
Read the guide →S
Source factory
A supplier that manufactures the products it sells rather than only reselling goods made by others.
GDXC is a source factory: the company is registered in Shenzhen and production is carried out in Dongguan.
Read the guide →W
Wall washer
A linear LED luminaire designed to light a vertical surface evenly from top to bottom, typically mounted at the base or top of a façade.
Beam angle and mounting distance decide whether the wash is even. A fixture chosen from a catalogue image without those inputs often produces hotspots or dark bands.
Read the guide →Warranty
The period during which the supplier commits to remedy defects in the supplied product under the stated terms.
All GDXC product lines — wall washers, linear lights, flood lights, in-ground lights and pixel lights — carry a 3-year warranty.
Read the guide →Send the drawing and effect requirement
Send a façade drawing or site photo with the effect you want. We will propose fixture families, control options and a project checklist — no obligation.